Filter Results By:

Products

Applications

Manufacturers

Showing results: 766 - 780 of 2632 items found.

  • Three Phase Load Bank

    REOLOAD 310 - REO Ltd.

    A three phase load bank rated for 48kW, with fan cooling. The front panel layout includes a switch panel for configuring the separate resistor modules to give the required resistance and current range. There are also digital panel meters for displaying the phase voltages and currents. An interface for PLC control is also provided.

  • Reactive Energy Regulator

    MASTER - Lifasa - International Capacitors, SA

    It measures the reactive power needs of an installation and gives the corresponding capacitor connection and disconnection orders to keep the cos φ preset. At the same time it allows to measure the main parameters of an installation (voltage, current, harmonics, active power, reactive power, etc.), by using 1 or 3 current measurement transformers.

  • Universal Function Test System

    UFTS-CM_20Ch/ 20Ch - Misum Systech Co., Ltd.

    All of the lithium batteries need protection circuit module to prevent any loss of battery function capacity and explosion during over charge , over current or short to cause increased temperatures. This equipment is used to test and inspect a battery's voltage, current, charge, discharge PCM status, IR, and others.

  • AC-DC High Voltage Power Supplies

    Acopian Technical Company

    These modular High Voltage supplies may be used as constant voltage or constant current sources. They may be remotely programmed by means of either voltage or resistance, and have provisions for remote monitoring and output inhibiting. All control and monitoring connections are on a pluggable terminal block that functions as a connector, providing wiring convenience and permitting easy and rapid connect/disconnect. Outputs are arc/short circuit protected.

  • Insulation Testers

    JP3X Series - Danbridge a/s

    The Danbridge non-destructive High Voltage Insulation Testers meet the demands for a gentle method of testing insulation condition and detecting leakage currents while protecting hardware, components and materials. Danbridge have two High Voltage Insulation Testers depending on requirements - JP30A can test using up to 30k volt, while JP36A is used when voltages up to 36k volt are desired.

  • Dielectric Loss Tangent Testing Instruments

    Soken Electric Co. Ltd

    Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.

  • Loop-Powered Transmitters and Drivers

    4-20mA - Riverhawk Company

    Loop-Powered Transmitters convert the output from proximity probes, seismic sensors, into a 4-20mA DC current, which is proportional to the input being measured. The transmitter converts the displacement or vibration signal to DC voltage and/or current for a DCS or PLC system. They control a 4-20mA current loop for a specified vibration range (ex. 0-5 mils peak-to-peak). The transmitters have a two-wire hook-up, powered solely by the loop current and have a power supply range of 15 to 36 volts.

  • DIP LED Aging Tester

    LS6100 - Lisun Electronics Inc.

    Designed to measure the aging-life and color comparisons of 260pcs DIP LED. • 260 separate constant current supply • Aging functions: constant current, impact pulse, on-off mode • Range of forward voltage(VF): 5.0V • Range of forward current(IF): 1) constant current: 0-100.0mA 2) Impact pulse: 0-200.0mA • Range of impact pulse frequency: 10-9999Hz; Duty ratio: 1%-99% • Range of on-off circle: 0-9999H59M59S • Range of on-off times: 0-9999times • Range of aging time: 0-9999H59M59S

  • 1000A AC/DC Clamp Meter

    CM84 - Martindale Electric Co. Ltd

    The CM84 is a high specification 1000A clamp meter, packed full of functions for the installation, testing and maintenance of domestic and industrial installations. It is light enough for easy one handed operation but still robust enough for use in harsh environments.

    This compact meter provides accurate measurement of AC voltage to 750V, DC voltage to 1000V and AC current to 1000A. It has the same test functions you would find on a high specification multimeter making this clamp a comprehensive testing solution for electricians, maintenance and service engineers. This has the added benefit of DC current measurement to 1000A and has a useful DC current zero function.

  • Bench Power Supply, DC, Single, Adjustable, 1 Output, 1 V, 36 V, 0 A, 3 A

    72-8345A - Tenma

    Switch Mode Laboratory DC Power Supplies Precision adjustable supply provides adjustable 1~36VDC output with adjustable current limiting from 0~3A. It is ideal for test, measurement and service applications where tight voltage and current regulation are critical. Highly efficient switch mode design delivers outstanding performance from an extremely compact footprint. Unique separate output ON/OFF control allows voltage and current setting, with the supply output turned off. Part of a Complete Series, this slim supply occupies little bench space while providing very high precision and 90W of continuous output.

  • Series Voltage References

    Analog Devices Inc.

    Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.

  • High Voltage Tester

    Electrocon Systems

    The High Voltage Tester supplied and exported by us is manufactured as per the set standards and regulations. This High Voltage Testers are available in AC and DC types and are used for testing HV cables after installation and repair for ensuring efficient performance. It also indicates voltage withstands level and current leakage level of the cable during the testing period. We manufacture High Voltage Tester using advanced technology and make it available in the market at affordable prices.

  • Digital Multimeters

    VOAC7523H / 7522H / 7520H / 7521H - IWATSU Electronic Co., Ltd.

    *Single VOAC7523H/7520H unit, equipped with a 2-channel DC measuring input and dual display, can perform DC voltage measuring that normally requires two units and thus saves installation space and improves measurement speed.*The VOAC7522H/7521H, equipped with one input channel and dual display, can perform current or frequency measuring simultaneously with voltage measuring.*The VOAC7523H/7522H realizes the high resolution of direct-current voltage measuring at 0.1µV and broad bandwidth of alternating voltage at up to 300kHz.

  • Digital (1kV below) Insulation Tester

    1851 IN - Standard Electric Works Co., Ltd

    ● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 210mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● BS 16 edition

  • Enhanced 16 Discrete/Switch I/O Channels (±80 V, 625 mA/Ch.)

    DT5 - North Atlantic Industries

    The DT5 module (the enhanced version) features 16 independent, isolated, programmable channels that can be used for input voltage measurements (±80 V), or as a bi-directional current switch (up to 500 mA per channel). When programmed as a switch with the switch closed, both the current through the switch and the voltage across the switch can be monitored. These modules include diode clamping on each channel. Clamping is useful for inductive loads, such as relays and short circuit protection. Additional features of the DT5 (Enhanced Version) are listed below.

Get Help